What is the operation method of the multifunctional water pump control valve?
The multifunctional water pump control valve is installed at the water outlet of the water pump. The main valve is first closed to about 90%. When the water pump stops running, the remaining 10% is closed again. It can effectively protect the water pump to prevent water hammer, water hammer sound and water pump reverse rotation. So everyone knows what is the operation method of the multifunctional water pump control valve?
Operation method of multifunctional water pump control valve:
1. When the pump is stopped, the valve plate is fully closed under the action of the static pressure of the outlet end and the upper chamber of the diaphragm.
2. When the water pump is started, the water pressure is introduced into the lower cavity from the bypass pipe, and the main valve plate and the slow-closing valve plate are slowly opened under the action of the water pressure at the inlet end and the lower cavity.
3. Under the action of the pressure at the water inlet, the valve plate rises to the maximum opening state, and the opening height is determined by the flow rate.
4. At the moment of stopping the pump, the flow and pressure suddenly drop, and the main valve plate begins to slide downward under the action of gravity.
5. The slow-closing valve plate completely closes the drain hole, and the valve returns to the initial state of stopping the pump.
6. When the flow is close to zero, the main valve is closed, and a drain hole is left on the main valve plate to weaken the impact of water hammer.
When we all operate the multifunctional water pump control valve, we can all operate and use our valve according to the above operation method. The correct operation and use of the multifunctional water pump control valve is very important for us.
Basic structure of multifunctional water pump control valve
What are the main performance specifications of the LHS941X flow regulator?